图2-15 热敏电阻的温度与感度变化
图2-16 温度差的测定回路
温度差的测定回路:
范围 | 温度(℃) | 放大倍数 | 误差(%) |
1 | 0~20 | 15.31 | ±0.5℃ |
2 | 20~40 | 13.94 | ±0.1℃ |
3 | 40~60 | 13.84 | ±0.2℃ |
4 | 60~80 | 14.67 | ±0.3℃ |
5 | 80~100 | 15.96 | ±0.3℃ |
误差系指感度误差 (±10℃差的测定时 )
表5 温度差输出: ( 图2-14电桥电路的方式 ):
温度℃ | 热敏电阻kΩ | 输出 (V) | 5℃温度差输出 (V) |
0 | 30.000 | 0.44547100 | -0.05452870 |
5 | 24.100 | 0.44712100 | -0.05287910 |
10 | 19.490 | 0.44850000 | -0.05149970 |
15 | 15.850 | 0.45003500 | -0.04996530 |
20 | 12.970 | 0.45135400 | -0.04864640 |
25 | 10.670 | 0.45276400 | -0.04723560 |
30 | 8.828 | 0.45408500 | -0.04591550 |
35 | 7.343 | 0.45538800 | -0.04461170 |
40 | 6.140 | 0.45658900 | -0.04341100 |
45 | 5.159 | 0.45780300 | -0.04219660 |
50 | 4.356 | 0.45901600 | -0.04098360 |
55 | 3.696 | 0.45988600 | -0.04011400 |
60 | 3.147 | 0.46131500 | -0.03868540 |
65 | 2.695 | 0.46229000 | -0.03770960 |
70 | 2.317 | 0.46328500 | -0.03671530 |
75 | 2.000 | 0.46438100 | -0.03561860 |
80 | 1.734 | 0.46514500 | -0.03485500 |
85 | 1.508 | 0.46638400 | -0.03361640 |
90 | 1.318 | 0.46704400 | -0.03295590 |
95 | 1.155 | 0.46823200 | -0.03176800 |
100 | 1.017 | 0.46865200 | -0.03134800 |
105 | 0.897 | 0.46954500 | -0.03045530 |
图2-17非反相输入放大器的连接
图2-18 反相输入电路连接
图2-19 电桥电路部分Δ-Y变换的简化
注:(1)0~100℃用,温度 - 电压变换输出100mV/℃( 平均感度Th 0℃为30KΩ)
(2)R1,R2,R3,R4的误差在01.%以下。
图2-20 与OP放大器共享电源
图2-21 温度控制器的结构
图2-22 温度控制电路 (ON/OFF)
图2-23 动作间隙
图2-24 ON/OFF控制产生的圈环
图2-25 比例控制电路